Skip to content
Special solutions · LightLineLed

IP68 full potting

LightLineLed brings the clear light line to demanding environments as well. The factory fully potted luminaire unit combines protected lighting technology with the design possibilities of the profile system. Whether façade, pool area, agriculture or industry: profile, potting, light effect and connection are matched to the actual application.

System concept · IP68 full potting
System concept · IP68 full potting
For your architecture

What this solution makes possible.

LightLineLed brings the clear light line to demanding environments as well. The factory fully potted luminaire unit combines protected lighting technology with the design possibilities of the profile system. Whether façade, pool area, agriculture or industry: profile, potting, light effect and connection are matched to the actual application.

Factory fully potted and sealed IP68 luminaire unit.

Individual light colour, output, shape, potting colour and connection cable length.

Installation, surface mounting, suspension and luminaire construction with matching profiles. Request lengths up to 6 m per project; coordinate profile, potting, heat dissipation and transport.

The solution in detail

This is how your line of light is made.

Application, construction and benefits – tailored to your architecture.

Protected lighting technology with familiar system design

Full potting turns the fitted visible profile into a factory-sealed luminaire unit. The potting itself forms the light-emitting surface; a separate cover is not required. Mini profiles, LL25, LL2515 and LL35F open up different forms. With matching powder-coated flush-mount profiles, the unit can be integrated into the architecture. Flangeless variants allow surface mounting, suspension and custom-built luminaires.

For environments that demand more

Depending on the confirmed version, solutions are possible for façades, pools with different water treatment systems, inspection pits, agriculture and industry. Salt/chlorine environment, UV, temperature as well as fuels, cleaning agents and solvents: confirm the suitability of the specific potting version for medium, concentration and temperature before manufacture. IP68 alone does not demonstrate these properties. Walkable and drivable versions require an approved load-bearing structure; define loads and abrasion/impact stress before manufacture.

Colour, shape and length according to your project

Light colour, output, luminaire shape, potting colour and connection cable length are defined together. Request lengths up to 6 m per project; coordinate profile, potting, heat dissipation and transport. Coloured potting can match the light line to the façade design. Because colouring affects light transmission and luminous flux, the desired effect is assessed on a sample in both the switched-on and switched-off state.

The finished light colour counts

The potting intended for this version shifts the light colour by about 300 K towards cooler. For a finished light colour of approximately 3000 K, a 2700 K flexible strip is therefore used. This is a property of this potting version, not a general rule for all potting materials. Especially with coloured potting, the finished light effect is sampled.

Route the supply concealed and protect it appropriately

In flush-mount profiles and with LL2509 as mounting base, the double base creates a cable level behind the visible profile. Mounting clips serve as fixing points and for cable routing. Additional feed points for longer light lines can thus be reached concealed; the maximum permissible feed length of the flexible strip remains decisive. This installation space is not automatically IP68-protected. Connections and power supply are planned to suit the environment.

The solution in section

Insights from the construction site

The system as construction progresses.

From the prepared housing to the finished light line.

The path to the finished light line

  1. Define application and light effect

    Coordinate environment, media, temperature, water exposure and mechanical loads with profile, light colour, output and shape.

  2. Factory assembly

    Define length, potting colour and cable outlet before manufacture. The finished unit is not sawn, drilled or opened afterwards.

  3. Integrating the finished luminaire

    Prepare the installation matched to the load, fasten and secure the luminaire to suit the mounting method. Design the connections and power supply for the place of use and connect them professionally.

For execution

Installation & documents.

The installation and processing instructions accompany the actual implementation of your line of light.

PDF

IP68 full potting · Installation & processing

PDF · matching instructions

PDF

Safety and installation notes

PDF · observe together with the instructions

PDF

The complete installation manual

All applications and system details

Processing notes in detailMounting clips, safety cable and further notes on the specific design

Build-up details

Possible visible profiles: Mini, LL25, LL2515 and LL35F. Use matching powder-coated flush-mount profiles for installation.

The potting forms the light-emitting surface; an additional cover is not needed. LL35F with flange for installation only; for surface mounting and suspension use flangeless visible profiles.

The IP68 version applies to the assembled luminaire, not automatically to the mounting profile, installation level or on-site connections.

Processing and installation

Salt/chlorine environment, UV, temperature as well as fuels, cleaning agents and solvents: confirm the suitability of the specific potting version for medium, concentration and temperature before manufacture. IP68 alone does not demonstrate these properties. Define immersion depth and duration as well as the intended water exposure on a product-specific basis.

Walkable and drivable versions require an approved load-bearing structure; define loads and abrasion/impact stress before manufacture. Plan pool installations separately for electrical requirements.

Do not saw, drill or open the potted unit. Do not put damaged units into operation.

Take heat dissipation and temperature-related length change into account; accept movement joints and do not constrain units. IP68 alone does not confirm suitability for high-pressure cleaning.

From possibilities to your project

Light line found.
We'll clarify the details together.

Building material, surface and desired lighting effect set the direction. MPW supports you with the right system version and the next steps.

Talk to MPW
References

Light lines in architecture.

Discover implemented LightLineLed solutions in different rooms and building materials.

Discover references

Open original view ↗