Thought through in detail.
Felt in everyday use.
Nine advantages of the LightLineLed system solution – from the prepared structure to later maintenance. Original drawings and project photos show the system; concrete examples explain the benefit.
Discover the nine advantages
Concealed cable routing
More feed points. One continuous light line.
In the suitable flush-mount profiles and with LL2509, the mounting level provides space for cables behind the visible profile, parallel to the flexible LED strip. Mounting clips serve as fixing points and for cable routing. Additional feed points can be reached along the light line.
Cable routing in the systemFor planning and execution
230 V supply lines to the transformer as well as 24/48 V lines to the LED strip are possible, depending on the design. Plan cable selection, required separation, cross-section and voltage drop professionally. The maximum feed length of the respective flexible strip remains decisive.
Adjust height
The surface grows. The light line follows.
If a concrete ceiling is subsequently filled or plastered, the finished surface height changes. With suitable mounting clips, the position of the visible profile is adjusted within the intended system combination. The installed mounting profile remains in place.
Discover mounting clipsFor planning and execution
The possible adjustment range depends on profile, clip and termination. Observe a secure latching fit and the current notes on V2/V3.
Technology in the light line
Service access without an additional inspection hatch.
Transformer tunnels or suitable transformer profile sections accommodate power supplies, dimmers and terminal points. Removing the visible profile gives access to the technology housed there. No separate inspection opening is required in the finished plasterboard surface for these components.
Understanding the technical roomFor planning and execution
Installation space, heat dissipation and removal route must suit the technology used.
Connecting trades cleanly
A prepared receptacle for the next work step.
The drywall installer integrates the mounting profile with flange. The surfaces are then filled and painted. The electrician takes over a defined system receptacle and inserts the light insert. With correct installation, subsequent adjustment of the cut-out is not required.
View the drywall solutionFor planning and execution
Installation and surface connection are coordinated between the trades.
Sampling in the finished room
Experience the light. Then select and order.
After the painting work, client and installer sample the suitable visible profiles directly in the actual room: frameless or with covered connection joint, different light colours, outputs and light effects. Only after selection are the visible profile, LED and matching technology ordered.
Compare profiles and terminationsFor planning and execution
The structural receptacle and supply are planned in advance; sampling takes place within the technically suitable combinations. The project photo shows a realised lighting solution; the specific light effect is sampled on site.
Manufacturing independently
Prepare at the workbench. Insert on site.
After the surfaces are finished, the installer takes the on-site measurements. The light insert is fitted in the workshop or a suitable site store, clean, dry and at suitable processing temperatures. This makes precise work easier and reduces long overhead work in the cold or at great heights.
Get to know the construction sequenceFor planning and execution
On site, the professional connection, fall protection, insertion and function test remain.
Servicing and modifying
The light unit goes in for service. The surface stays.
In the event of failures or new requirements, the light insert can be removed, repaired or modified at the workbench and reinserted. Other outputs or additional LED strips are also possible with suitable profile and technology design. The mounting level supports the cable routing needed for this.
Removal and securingFor planning and execution
Check mechanics, heat dissipation, supply and control together when making changes. Potted units are serviced or replaced as a unit, depending on their version.
Two levels of movement
Absorb temperature movements. Relieve connections.
In the ETICS version intended for this, connection profiles form the first level of movement between the façade surface and the flush plaster profile. The mounting-clip receptacle forms the second level between the flush plaster profile and the light insert. In this way, temperature-induced movements can be taken into account and stresses at the connections reduced.
Façade connection in detailFor planning and execution
With professional execution, the risk of connection cracks is reduced. This refers to structural movement compensation – not a proven complete thermal separation and not a blanket guarantee against cracks.
Expansion in the assembly
Linear connectors guide the profile sections together.
Suitable linear connectors couple the visible profile sections into a continuous run. This reduces uncontrolled relative movement at the connected profile joints. It supports material-friendly routing of the flexible LED strips across these areas.
Planning length expansion correctlyFor planning and execution
The entire run requires planned room for movement. Fixed points, joints, end caps and strip routing must fit together; a connector does not replace this design. Before cutting, measure the temperature of profile and cover, allow sufficient clearance and clip the cover in without stress.
Visible parts stay out of the construction phase.
The visible profile, LED and cover are only inserted after the surface work. This means they are not exposed at the installation point during plastering, sanding and painting. This reduces soiling and the risk of damage.
What sets profile-in-profile apart?
Comparison with single profiles plastered in directly. Surface-mounted, removable or otherwise constructed single profiles may have different properties.
| Task | LightLineLed system solution | Directly installed single profile |
|---|---|---|
| Construction sequence | Mounting profile early, removable light insert late. | With single profiles plastered in, the LED carrier remains in the structure; protect it during surface work. |
| Design | Suitable visible profiles and terminations can be sampled in the same receptacle. | With permanently installed profiles, profile geometry and connection are defined early; covers and LEDs can be changed depending on the model. |
| Service | Remove the entire intended light insert and work on it at the workbench. | LED and cover can often be replaced; the plastered-in profile body usually remains on site. |
| Technical access | Suitable transformer tunnel with planned access via the light line. | Depending on model: external supply or integrated technical space possible. Separate inspection not generally required. |
| Height adjustment | Via suitable mounting clips within the system range. | With a permanently plastered-in LED carrier, determined by its installation height. |
| Material movement | Levels of movement and connectors are planned together with room for movement. | Single profiles also need expansion planning related to material and installation. |
Basis of comparison: LightLineLed system and product pages and manufacturer information on the KLUŚ KOZUS-50 (integrable power supply and protective insert for installation). As of: 17 Nov 2026. Not a blanket comparison of all single-profile solutions.
The solution for your project.
Light line found.
We'll clarify the details together.
Building material, surface and desired lighting effect set the direction. MPW supports you with the right system version and the next steps.