Guides

How much light does each room need? Lux levels for homes and offices

In short: For workplaces, ÖNORM EN 12464-1 specifies maintained values that must not be undercut during operation: 500 lux for writing, reading and screen work in offices, 300 lux for filing and copying, 100 lux for corridors. There are no binding values for private living spaces; as a guide, around 100–200 lux applies for general lighting in the living room and around 500 lux at work surfaces such as the kitchen worktop or desk.

Living area with a sofa and vertical LED light lines in the wall

What does lux mean – and how does it differ from lumen?

Lumen (lm) describes how much light a light source emits in total. Lux (lx) describes how much of it reaches a surface: 1 lux corresponds to 1 lumen per square metre. To answer the question of whether it is bright enough, what counts is therefore the illuminance in lux – measured where the seeing takes place: on the work surface at a desk, on the floor in a corridor.

How many lux a luminaire produces depends not only on its luminous flux but also on distance, beam angle, room size and surfaces: light walls reflect light more strongly, dark surfaces absorb it.

Which lux levels apply in offices?

For indoor workplaces, the European standard EN 12464-1 is decisive, in Austria as ÖNORM EN 12464-1. For each visual task it specifies a maintained illuminance (Ēm): the lighting must not fall below this value during operation – not even when luminaires age and become soiled. In addition, there are requirements for glare (UGR), uniformity and colour rendering (Ra).

Extract from EN 12464-1 for offices and circulation areas. The edition of the standard in force applies.
Area / activityĒm (lux)UGR max.Ra min.
Writing, reading, data processing5001980
Technical drawing7501680
CAD workstations5001980
Conference and meeting rooms5001980
Filing, copying3001980
Reception desk3002280
Archives2002580
Circulation areas and corridors1002840

Since the 2021 edition, the standard additionally specifies increased illuminance values. They apply when the visual task is particularly demanding, errors would be costly or the visual capacity of employees is lower – for example in older staff. Lower values are permitted for the surrounding area around the workplace.

The values apply to an assessment area, not to a single measuring point. Whether a design meets them is shown by a lighting calculation with DIALux.

How much light does a living space need?

There are no binding lux requirements for private living spaces. The following values are guide values from planning practice, not standard values. They help you estimate the order of magnitude; personal perception, the age of the occupants and the desired atmosphere can justify significantly different values.

Guide values for private living spaces, not a standard requirement.
Room / areaGuide value (lux)Note
Hallway, entrance, stairs100–150light steps so they are clearly visible
Living room, general lighting100–200dimmable for an evening atmosphere
Reading in an armchair or on the sofa300–500targeted with a reading light
Dining table200–300glare-free above the table
Kitchen, general lighting200–300uniform throughout the room
Kitchen worktop500shadow-free, e.g. with lighting under the wall cabinets
Bathroom, general200pay attention to the protection rating
Bathroom mirror300–500from the side or around the face, not only from above
Bedroom100warm white and dimmable
Home office desk500based on the office values of EN 12464-1

In living areas, the interplay of general, accent and ambient lighting matters more than the one correct lux figure. Bright general lighting alone quickly looks sober; several dimmable light sources, by contrast, allow brightness to be adapted to the time of day and activity.

Which colour of light suits which room?

Besides brightness, the colour temperature determines how a room feels:

  • Warm white (2,700–3,000 K): cosy and relaxing, ideal for living rooms and bedrooms.
  • Neutral white (3,500–4,500 K): promotes concentration, good for kitchens and work areas.
  • Daylight white (5,000–6,500 K): activating and clear, suitable for offices or bathrooms.

For natural colour rendering, a high colour rendering index is recommended in living spaces; for most workplaces, EN 12464-1 requires at least Ra 80.

How many lumens does a room need? A worked example

A rough estimate is provided by the formula: required luminous flux = illuminance × area ÷ (utilisation factor × maintenance factor). The utilisation factor indicates how much light actually reaches the working plane; it depends on the luminaires, room geometry and reflections. The maintenance factor takes ageing and soiling into account.

Example: a 12 m² home office is to reach 500 lux throughout. With an assumed utilisation factor of 0.5 and a maintenance factor of 0.8, this gives 500 × 12 ÷ (0.5 × 0.8) = 15,000 lumens. That is a lot – which is why, in practice, moderate general lighting is usually combined with a task light that illuminates the desk surface specifically.

The formula does not replace a lighting calculation: the position of the luminaires, light distribution and glare can only be assessed reliably with a simulation.

How can you make sure the values are achieved in the finished room?

For workplaces, calculation-based design is the usual approach: a lighting calculation simulates illuminance, uniformity and glare before luminaires are ordered. In living areas, professional lighting design helps to put the right luminaires in the right places and to plan outlets in good time. MPW works according to current standards such as ÖNORM EN 12464-1. MPW will answer questions about your project in a free initial consultation.

FAQ

Frequently asked questions

How many lux does an office workstation need?

For writing, reading and screen work, EN 12464-1 specifies a maintained illuminance of 500 lux in the task area, together with a UGR limit of 19 and a colour rendering index of at least Ra 80.

Is there a standard for lighting living spaces?

No, there are no binding lux requirements for private living spaces. The values in this guide are guide values from planning practice.

What is the difference between lux and lumen?

Lumen is the total luminous flux of a light source, lux the illuminance on a surface. 1 lux corresponds to 1 lumen per square metre.

Can I measure illuminance myself?

Yes, with a lux meter placed on the surface to be assessed. For verification in line with the standard at workplaces, the values are calculated in advance and checked on a measuring grid after installation.

More guides

When should lighting design start in a new build – and what does it cost?

When lighting design should start in a new build, what it costs at MPW (from €500 net) and which mistakes can hardly be corrected once the shell is complete.

Installing light lines in concrete: what must be decided before pouring?

Light lines in cast-in-place and fair-faced concrete: which decisions must be made before pouring – routing, surface, technical space, cabling and statics.

LED light lines in drywall and timber: which profile, which cover, how much heat?

LED light lines in plasterboard, OSB, solid timber and CLT: which recessed profile fits, which cover belongs to which profile and how much power is possible.

DIALux lighting calculation: when is proof required and what does it contain?

When a DIALux lighting calculation is useful or required as proof, which values it contains, which documents are needed and what it costs at MPW.

Planning LED strips properly: colour temperature, CRI, IP rating, power supply and dimming

How to plan LED strips: suitable colour temperature, CRI, IP rating, power supply, power feed and dimming – with tables and a worked example for 24 and 48 V.

How Many Lux Does a Room Need? Values for Home and Office