Guides

DIALux lighting calculation: when is proof required and what does it contain?

In short: A lighting calculation with DIALux is needed whenever it must be shown that lighting meets certain requirements – above all at workplaces under ÖNORM EN 12464-1. It contains illuminance, uniformity, glare rating and colour rendering for each assessment area, the luminaire list and false-colour and isoline displays. MPW charges €150 net per hour for a DIALux lighting calculation.

Canteen with long suspended LED pendant luminaires above the rows of tables

What is a DIALux lighting calculation?

DIALux is widely used software for designing and calculating lighting. The room is created as a 3D model with dimensions, surfaces and furniture, and the planned luminaires are inserted with their photometric data. From this, the software calculates how much light reaches which surfaces, how evenly it is distributed and whether glare is to be expected.

Lighting design and lighting calculation complement each other: lighting design defines which light is needed where and which luminaires are used. The lighting calculation proves mathematically that illuminance, uniformity and glare meet the requirements.

When is a calculated verification required?

No particular program is prescribed – what is required is that the lighting meets the requirements. A calculation is the usual way to demonstrate this before installation. Typical occasions:

  • Workplaces: offices, production, warehouses, workshops and sales areas – the requirements of ÖNORM EN 12464-1 apply here.
  • Tenders and client specifications: architects, general contractors or public clients frequently require a calculation as part of the planning documents.
  • Subsidies and refurbishments: if a subsidy is applied for to renew lighting, evidence regarding the lighting may be requested; the calculation provides the values for this.
  • Emergency lighting: minimum requirements also apply to escape routes, and these can be verified by calculation.
  • Demanding residential projects: no obligation to provide proof, but useful when light lines, indirect lighting or large rooms are planned and bad purchases are to be avoided.

A calculation is also worthwhile for smaller projects: especially with a limited budget or complex architecture, it provides clear decisions and often surprisingly great potential for optimisation.

What does a lighting calculation contain?

Which values appear in the report depends on the project and the requirements.
ResultWhat it tells you
Maintained illuminance Ēm (lux)average illuminance on the assessment area, which must not be undercut during operation
Uniformity U₀ratio of minimum to average illuminance – shows dark zones and shadows
Glare rating UGRwhether the luminaires cause glare from typical viewing directions
Colour rendering Rafrom the luminaire data; at least 80 for most workplaces
False-colour and isoline displaywhere in the room how much light arrives, at a glance
Luminaire list and positionstype, quantity, luminous flux and position of each luminaire
Maintenance factorwhich ageing and soiling were assumed
Connected loadelectrical power of the lighting, also in relation to the floor area

At MPW you also receive a detailed lighting plan with information on illuminance, colour of light and luminaire placement, suggestions for suitable luminaires and a rough budget estimate.

What does a lighting calculation achieve beyond verification?

A calculation prevents over- and under-lighting and saves energy, because the installation is designed to meet actual needs instead of being made too bright "to be on the safe side". Typical areas of application show the effect in practice:

  • Offices: glare-free workstations with good light distribution for focused work and less fatigue.
  • Industrial halls: efficient lighting of large areas, fewer shadow zones and greater occupational safety.
  • Retail and showrooms: targeted lighting accents that direct attention.
  • Living spaces: lighting moods that become visible in advance – before a single luminaire has been bought.

Which documents does the lighting designer need?

  • Room size and geometry: floor plans and sections with ceiling heights. A high room needs different luminaires from a low one, and angled areas need special solutions.
  • Colours and materials: light walls reflect more light than dark ones; timber, glass and metal also influence the lighting effect.
  • Use and visual task: a workplace needs different values from a living room or a shop window.
  • Furniture: position of workstations, shelving and built-in elements.
  • Luminaire data: for each luminaire, a photometric data set is required, for example in LDT format, that matches the actual configuration.

For LightLineLed light lines, MPW provides photometric data for specifically measured combinations – in the verified data set, twelve 1 m combinations at 3,000 K of profile, LED strip and cover. If the configuration differs, for example due to a different length, colour of light or cover, suitable light data must be requested separately. More under lighting design, output and LDT data.

When should the lighting calculation be prepared?

Ideally right after the planning-permission drawings. Power outlets, luminaire positions and controls can then be integrated early on and later extra costs avoided. For refurbishments, the calculation is based on a survey of the existing lighting.

It is just as important that the design is implemented precisely on site. The best calculation is of little use if luminaires are mounted in places other than those planned. The calculated light points can therefore be marked out on site – so that the planned, uniform lighting that complies with the standard is retained in the finished room.

What does a DIALux lighting calculation cost at MPW?

According to the overview of services, the DIALux lighting calculation is charged by time spent at €150.00 net (€180.00 incl. 20% VAT) per hour. The number of hours depends on the number and complexity of the rooms. Comprehensive lighting calculations and simulations are also part of the premium project planning (€2,000.00 net) and the all-inclusive package (€3,500.00 net).

On request, MPW also comes to the construction site: to coordinate with architects and specialist tradespeople, to mark out the lighting outlets or to assess existing lighting. These appointments are charged by time spent at the hourly rates in the overview of services, plus €0.50 net per kilometre; if the lighting concept is commissioned directly after the lighting design, these costs are waived. All details can be found on the lighting calculation page.

FAQ

Frequently asked questions

Is a lighting calculation required by law?

No particular program is prescribed. At workplaces, however, the lighting requirements must be met; a calculation is the usual way to prove this before installation.

Does MPW's lighting calculation comply with the standards?

Yes. MPW works according to current standards such as ÖNORM EN 12464-1 and takes into account requirements for workplaces, emergency lighting or eligibility for subsidies.

Is a lighting calculation also useful for smaller projects?

Yes. Especially with a limited budget or complex architecture, a targeted calculation provides clear decisions and often surprisingly great potential for optimisation.

What is an LDT file?

An LDT file in EULUMDAT format describes the light distribution of a luminaire. Programs such as DIALux need it to calculate the luminaire realistically; it must match the actual configuration.

More guides

When should lighting design start in a new build – and what does it cost?

When lighting design should start in a new build, what it costs at MPW (from €500 net) and which mistakes can hardly be corrected once the shell is complete.

Installing light lines in concrete: what must be decided before pouring?

Light lines in cast-in-place and fair-faced concrete: which decisions must be made before pouring – routing, surface, technical space, cabling and statics.

LED light lines in drywall and timber: which profile, which cover, how much heat?

LED light lines in plasterboard, OSB, solid timber and CLT: which recessed profile fits, which cover belongs to which profile and how much power is possible.

How much light does each room need? Lux levels for homes and offices

Lux levels according to EN 12464-1 for offices and workplaces plus guide values for living spaces – with tables, lux and lumen explained and an example.

Planning LED strips properly: colour temperature, CRI, IP rating, power supply and dimming

How to plan LED strips: suitable colour temperature, CRI, IP rating, power supply, power feed and dimming – with tables and a worked example for 24 and 48 V.

DIALux Lighting Calculation: When It Is Needed and Contents