Guides

LED light lines in drywall and timber: which profile, which cover, how much heat?

In short: In plasterboard ceilings and in timber construction with OSB, a mounting profile with 13 mm flanges sits concealed behind the boarding, suitable for 12.5 and 15 mm plasterboard; in exposed solid timber or CLT, the concrete recessed profile is set into a precisely milled recess. The cover depends on the profile and mounting type, the LED output on the tested combination: for flush-mounted installation up to 22 W/m at 25 °C, but only up to 10 W/m at an ambient temperature of 45 °C.

Sales room with timber slats on the ceiling and LED light lines running between them

Which installation detail suits which substrate?

Ceiling or wall, plasterboard or timber: the principle of the LightLineLed system is always the same. A housing is prepared during interior finishing, and the luminaire insert follows after the surface work. What differs is how the housing is fixed in the respective material.

Source: LightLineLed application pages and installation documents from MPW.
SubstrateHousingFixing and special features
Plasterboard ceiling (12.5 or 15 mm)Mounting profile with 13 mm flangeThe flanges lie behind the boards; screw through the board into the flange on each side from the room side. Clarify clashes with CD profiles early.
Timber construction with OSB and plasterboardMounting profile with 13 mm flangeFix the flanges to the OSB board, countersink the screws flush, then apply the boarding.
Solid timber and CLT (exposed)Concrete recessed profile in a milled recessFixed through the back of the profile into load-bearing timber; no additional plaster or plasterboard layer is intended.
Cavity in plasterboard, timber or suitable facade panelsRecessed and visible profile LL35Finserted directly into the opening with recessed mounting springs

In the variants with a mounting profile, this is 37 mm deep and the driver section 64 mm – each measured from the finished surface. The deeper driver section accommodates power supplies and connections and needs free installation space behind the boarding.

How is a light line installed in a plasterboard ceiling?

  1. Coordinate ceiling and technology: define the light routing, supporting structure, driver position and power feed before boarding and pull in the supply cable in good time.
  2. Install the recessed profiles: connect the profiles in alignment and attach them to the load-bearing substructure. Hangers, spacings and fixings are matched to the ceiling system and the additional load.
  3. Connect and fill the boards: screw through the boards into the flanges on both sides and insert the protective strip. With 15 mm plasterboard, an edge protector is placed on the inside of the profile.
  4. Fit the light: only after painting, expose the channel, determine the installation depth and connect, secure and click in the prefabricated light insert.

The plasterboard ceiling shown in the documentation is an example without fire-protection requirements. For classified fire-rated ceilings, the suitability of the entire ceiling build-up must be clarified separately. Details are shown on the application page light lines in plasterboard ceilings.

What needs to be considered in timber construction?

In timber construction with OSB, the OSB board provides the fixing base and the plasterboard the visible room finish. It is important that the light line does not weaken the wall build-up: bracing or airtight layers must not be interrupted without checking, and fire-protection requirements and sealing layers must be coordinated separately. Timber and OSB are processed dry and acclimatised.

With exposed solid timber or cross-laminated timber (CLT), the timber soffit remains the finished surface. The position and depth of the milled recess are defined with the timber engineer and structural engineer, and the fit is checked on a sample. Solid timber has a continuous grain direction, whereas CLT alternates between longitudinal and transverse layers. The flush solution uses V1 mounting clips with 10 mm. More on the page light lines in timber construction with OSB and plasterboard.

Which cover suits which profile?

Not every visible profile fits every cover – the profile geometry and mounting type determine the combination. Covers with side flanges are intended for recessed installation and cover the joint to the building element.

Extract from the confirmed LightLineLed combinations.
Visible profileCoverMounting typeEffect
LL25V1-AP-25recessed, surface, pendantflat finish, with a lateral shadow gap when recessed
LL25V2-UP-35 / V3-UP-50recessed onlyside cover flanges for the connection to the building element
LL35FV1-AP-25recessed onlyvisible aluminium flanges on the profile cover the joint
LL2515V5-U-2510recessed, surface, pendantwide, sculptural light output
LL2511EV6-E-2511recessed, surface, pendantlight output inclined by 45°

The complete overview can be found under combining profiles and covers. Uniformity, light output and glare always result from the specific combination of cover and LED strip – sampling is worthwhile.

How much LED output can a recessed light line take?

LED strips generate heat that has to be dissipated via the aluminium profile. In drywall and timber construction, the profile sits in a cavity or in a material with poor thermal conductivity – this limits the sensible output. The MPW thermal data sheet gives the following recommendations for tested combinations:

Recommendations, not test maxima; based on an LED Tc limit of 60 °C. Other configurations and installation positions must be assessed separately.
Installation situation (tested combination)at 25 °C ambientat 45 °C ambient
Flush-mounted in brick, plasterboard, timber, ETICS – LL25/LL35 + V1, LL2515 + V1/V5up to 22 W/mup to 10 W/m
Concrete – LL2515 + V1/V5up to 22 W/mup to 15 W/m
Surface/pendant – LL25 + V1up to 22 W/mup to 10 W/m

Sticking an LED strip directly onto timber or plastic does not provide the same heat dissipation as an aluminium profile. Heat build-up under insulation or in tightly enclosed cavities also raises the temperature.

Why does the cover need room to move?

Aluminium and the PMMA cover expand differently. When heated from 20 to 40 °C, 5 m of aluminium grows by about 2.3 mm and 5 m of PMMA by about 6.3 mm – a difference of around 4 mm. The component temperature is therefore measured before cutting, room for movement is planned at joints and end caps, and the cover is clipped in free of stress. As part of its custom assembly service, MPW cuts profiles and covers to size on request.

FAQ

Frequently asked questions

When is the lighting technology fitted in drywall?

After the filling and painting work. Until then the profile opening remains protected; afterwards the prepared and tested luminaire insert is connected and fitted.

Does the system also work with 15 mm plasterboard?

Yes. The installation documents show connections for 12.5 mm and 15 mm boards. With 15 mm, an edge protector is placed on the inside of the profile and held in position by a polystyrene insert.

Can I stick an LED strip directly onto timber?

Bonding onto timber does not provide the same heat dissipation as an aluminium profile. The Tc and Ta limits of the strip must still be observed; at higher outputs, a profile is the safe choice.

Is a recessed light line automatically suitable for damp rooms?

No. The fact that a profile can be recessed is not a protection rating for the complete luminaire. LED configuration, connection, sealing and control gear must suit the installation location as a complete assembly.

More guides

When should lighting design start in a new build – and what does it cost?

When lighting design should start in a new build, what it costs at MPW (from €500 net) and which mistakes can hardly be corrected once the shell is complete.

Installing light lines in concrete: what must be decided before pouring?

Light lines in cast-in-place and fair-faced concrete: which decisions must be made before pouring – routing, surface, technical space, cabling and statics.

How much light does each room need? Lux levels for homes and offices

Lux levels according to EN 12464-1 for offices and workplaces plus guide values for living spaces – with tables, lux and lumen explained and an example.

DIALux lighting calculation: when is proof required and what does it contain?

When a DIALux lighting calculation is useful or required as proof, which values it contains, which documents are needed and what it costs at MPW.

Planning LED strips properly: colour temperature, CRI, IP rating, power supply and dimming

How to plan LED strips: suitable colour temperature, CRI, IP rating, power supply, power feed and dimming – with tables and a worked example for 24 and 48 V.

LED Light Lines in Drywall and Timber: Profiles and Heat