Which installation detail suits which substrate?
Ceiling or wall, plasterboard or timber: the principle of the LightLineLed system is always the same. A housing is prepared during interior finishing, and the luminaire insert follows after the surface work. What differs is how the housing is fixed in the respective material.
| Substrate | Housing | Fixing and special features |
|---|---|---|
| Plasterboard ceiling (12.5 or 15 mm) | Mounting profile with 13 mm flange | The flanges lie behind the boards; screw through the board into the flange on each side from the room side. Clarify clashes with CD profiles early. |
| Timber construction with OSB and plasterboard | Mounting profile with 13 mm flange | Fix the flanges to the OSB board, countersink the screws flush, then apply the boarding. |
| Solid timber and CLT (exposed) | Concrete recessed profile in a milled recess | Fixed through the back of the profile into load-bearing timber; no additional plaster or plasterboard layer is intended. |
| Cavity in plasterboard, timber or suitable facade panels | Recessed and visible profile LL35F | inserted directly into the opening with recessed mounting springs |
In the variants with a mounting profile, this is 37 mm deep and the driver section 64 mm – each measured from the finished surface. The deeper driver section accommodates power supplies and connections and needs free installation space behind the boarding.
How is a light line installed in a plasterboard ceiling?
- Coordinate ceiling and technology: define the light routing, supporting structure, driver position and power feed before boarding and pull in the supply cable in good time.
- Install the recessed profiles: connect the profiles in alignment and attach them to the load-bearing substructure. Hangers, spacings and fixings are matched to the ceiling system and the additional load.
- Connect and fill the boards: screw through the boards into the flanges on both sides and insert the protective strip. With 15 mm plasterboard, an edge protector is placed on the inside of the profile.
- Fit the light: only after painting, expose the channel, determine the installation depth and connect, secure and click in the prefabricated light insert.
The plasterboard ceiling shown in the documentation is an example without fire-protection requirements. For classified fire-rated ceilings, the suitability of the entire ceiling build-up must be clarified separately. Details are shown on the application page light lines in plasterboard ceilings.
What needs to be considered in timber construction?
In timber construction with OSB, the OSB board provides the fixing base and the plasterboard the visible room finish. It is important that the light line does not weaken the wall build-up: bracing or airtight layers must not be interrupted without checking, and fire-protection requirements and sealing layers must be coordinated separately. Timber and OSB are processed dry and acclimatised.
With exposed solid timber or cross-laminated timber (CLT), the timber soffit remains the finished surface. The position and depth of the milled recess are defined with the timber engineer and structural engineer, and the fit is checked on a sample. Solid timber has a continuous grain direction, whereas CLT alternates between longitudinal and transverse layers. The flush solution uses V1 mounting clips with 10 mm. More on the page light lines in timber construction with OSB and plasterboard.
Which cover suits which profile?
Not every visible profile fits every cover – the profile geometry and mounting type determine the combination. Covers with side flanges are intended for recessed installation and cover the joint to the building element.
| Visible profile | Cover | Mounting type | Effect |
|---|---|---|---|
| LL25 | V1-AP-25 | recessed, surface, pendant | flat finish, with a lateral shadow gap when recessed |
| LL25 | V2-UP-35 / V3-UP-50 | recessed only | side cover flanges for the connection to the building element |
| LL35F | V1-AP-25 | recessed only | visible aluminium flanges on the profile cover the joint |
| LL2515 | V5-U-2510 | recessed, surface, pendant | wide, sculptural light output |
| LL2511E | V6-E-2511 | recessed, surface, pendant | light output inclined by 45° |
The complete overview can be found under combining profiles and covers. Uniformity, light output and glare always result from the specific combination of cover and LED strip – sampling is worthwhile.
How much LED output can a recessed light line take?
LED strips generate heat that has to be dissipated via the aluminium profile. In drywall and timber construction, the profile sits in a cavity or in a material with poor thermal conductivity – this limits the sensible output. The MPW thermal data sheet gives the following recommendations for tested combinations:
| Installation situation (tested combination) | at 25 °C ambient | at 45 °C ambient |
|---|---|---|
| Flush-mounted in brick, plasterboard, timber, ETICS – LL25/LL35 + V1, LL2515 + V1/V5 | up to 22 W/m | up to 10 W/m |
| Concrete – LL2515 + V1/V5 | up to 22 W/m | up to 15 W/m |
| Surface/pendant – LL25 + V1 | up to 22 W/m | up to 10 W/m |
Sticking an LED strip directly onto timber or plastic does not provide the same heat dissipation as an aluminium profile. Heat build-up under insulation or in tightly enclosed cavities also raises the temperature.
Why does the cover need room to move?
Aluminium and the PMMA cover expand differently. When heated from 20 to 40 °C, 5 m of aluminium grows by about 2.3 mm and 5 m of PMMA by about 6.3 mm – a difference of around 4 mm. The component temperature is therefore measured before cutting, room for movement is planned at joints and end caps, and the cover is clipped in free of stress. As part of its custom assembly service, MPW cuts profiles and covers to size on request.