Tiled stud wall

Light lines structure the tile pattern and highlight wall surfaces. LightLineLed creates a coordinated transition between the light opening and the covering.

System idea · Tiled stud wall
System idea · Tiled stud wall
For your architecture

What this solution makes possible.

The line of light becomes part of the tile pattern. The profile with 13 mm wing sits on the plasterboard; tile, adhesive and waterproofing are matched up to the profile edge. This allows light and flooring or wall covering to be brought together structurally.

Flush finish between light opening and tiled surface.

Two documented wall build-ups with a common connection idea.

Luminaire installation follows after the tiling work.

The solution in detail

This is how your line of light is made.

Application, construction and benefits – tailored to your architecture.

Designing light and tile pattern together

With LightLineLed, the line of light can be incorporated into the grid and surface of a tiled stud wall. It can form a vertical division, emphasise a room edge or deliberately highlight an area. The effect arises from the interplay of tile format, grout pattern and light output. The recessed profile creates a defined channel for this, the position of which is fixed before the tiling work. The lighting thus becomes part of the wall design and complements the chosen material.

A coordinated transition to the finished surface

The profile with 13 mm wing sits on the plasterboard cladding and is connected to a suitable load-bearing fixing substrate. Waterproofing, adhesive and tile are coordinated with the profile edge to the finished surface. The documented variants show both OSB with plasterboard and a double plasterboard cladding. The complete wall build-up is decisive. This allows drywall, tiling and lighting design to use the same visible termination as a shared planning basis.

The lighting technology follows the flooring work

While waterproofing and tiling are carried out, the opening stays protected. The fitted luminaire insert is only installed after this work is finished. This keeps sensitive profile surfaces, LED components and covers free of adhesive and construction-site dirt. A suitable driver profile section can complement the intended technical space. The lighting effect is determined by the matching visible profile, the cover and the equipment, while the structural housing is already prepared with the wall.

Think about accessibility from the start

Separating the installation body from the luminaire insert offers advantages for later maintenance: with the intended removal path, the suitable light unit can be reached while the tiled wall build-up remains in place. In areas exposed to moisture, building waterproofing, connections and the protection rating of the finished luminaire are planned to suit the installation position. Profile and cover alone do not replace waterproofing. The result is a detail in which the desired spatial effect and the requirements of the specific use are considered together.

The solution in section

Insights from the construction site

The system as construction progresses.

From the prepared housing to the finished light line.

The path to the finished light line

  1. Define the wall and installation space

    Coordinate studwork, cladding, backing and the 37/64 mm profile depths. Also consider the finished tile grid and transformer zone.

  2. Connecting and fastening profiles

    Connect mounting and transformer profiles flush and close the ends. The transition end cap closes the height difference. Adapt fasteners to the wall build-up and load.

  3. Continue the sealing without gaps

    Continue the waterproofing layer at the sides and behind the profile. Seal ends, joints, screw and cable penetrations tightly into the project-specific waterproofing detail.

  4. Complete the floor covering and luminaire

    Lay tiles flush and form the connection joint to accommodate movement. Protect the opening during the works; then clean, secure the light insert and clip it in.

For execution

Installation & documents.

The installation and processing instructions accompany the actual implementation of your line of light.

PDF

Tiled stud wall · Installation & processing

PDF · matching instructions

PDF

Safety and installation notes

PDF · observe together with the instructions

PDF

The complete installation manual

All applications and system details

Processing notes in detailMounting clips, safety cable and further notes on the specific design

Build-up details

Example 1: 19 mm OSB plus 12.5 mm plasterboard on the room side. Example 2: two layers of 12.5 mm plasterboard on the room side. Both are examples without fire protection requirements.

The profile wings rest on the plasterboard. Fasten through the board into load-bearing OSB or a planned backing.

13 mm from the front of the wing are available for the coordinated floor build-up of waterproofing, adhesive and tile; take the wing thickness into account.

Processing and installation

Mounting clips V2 (20 mm) and V3 (30 mm) may be shortened. Afterwards, both side legs must again taper inwards at an angle and form tips like the original tips. Blunt or straight-cut leg ends cause the clips to break when snapping in. Bevel both legs accordingly, deburr the cut points and check the tip shape before installation. Then check for full snap-in seating and secure hold. Do not use damaged clips. No blanket shortening dimension or cutting angle.

An aluminium profile or cover does not replace building waterproofing. Match protection rating, installation position and sealing build-up to the specific moisture exposure.

The retaining clip of the fall protection locks exclusively into the mounting profile, never into the flush-mount driver profile. If the light line begins with 0.5 or 1 m of driver profile, the upper securing fixing lies only in the adjoining mounting profile. A continuous flush-mount driver profile does not allow this type of securing; every lighting element must still be secured.

Four mounting clips per metre, rounded up and at least two per section. V1: 10 mm, V2: 20 mm, V3: 30 mm – choose to match the actual fit-out height. Secure visible profiles at the start, at every joint and at the end; the connector pair sits in both rear longitudinal slots of the suitable visible profile.

In the flush-mount driver profile, maximum driver installation height is 18 mm; remove the pull-out tab only after complete installation. MPW recommends routing the conduit in at the start of the driver profile, not through the end caps. Keep the electronics, terminal point and inspection access accessible.

Before cutting, measure the temperature of the profile and cover. Allow room for movement at joints and end caps for heating and cooling, and clip in the cover free of stress.

From possibilities to your project

Light line found.
We'll clarify the details together.

Building material, surface and desired lighting effect set the direction. MPW supports you with the right system version and the next steps.