Skip to content
Interior fit-out · LightLineLed

Clay plaster

Natural surfaces and contemporary light belong together. LightLineLed integrates a precise line of light into the multi-layer clay plaster build-up.

System concept · Clay plaster
System concept · Clay plaster
For your architecture

What this solution makes possible.

A multi-layer clay plaster build-up can also accommodate a flush light line. The documented detail connects the timber substructure, OSB, reed mat and clay plaster with the concrete installation profile. The finished plaster surface ends at the profile edge.

Light integration into a mineral, handcrafted surface build-up.

A clearly defined height level made of OSB and plaster.

Separate plastering and lighting installation with a protected profile channel.

The solution in detail

This is how your line of light is made.

Application, construction and benefits – tailored to your architecture.

Combining natural surfaces with precise light lines

A hand-crafted clay plaster surface and a clear light line can complement each other in design terms. LightLineLed integrates the lighting into the intended layer build-up so that the finished plaster surface runs right up to the profile edge. The line can emphasise room axes or accompany individual zones of use while the material effect of the clay plaster is preserved. The same basic design idea as in other LightLineLed applications can thus also be realised in a fit-out with clay plaster.

The profile connection follows the plaster build-up

The detail shown combines a timber substructure with OSB, reed mat and multi-layer clay plaster. The recessed profile is fastened to the substructure and forms the prepared housing for the later light insert. The layers are matched in height so that plaster and profile edge line up in the end. For planning, this offers a concrete starting point: the light opening is defined together with the surface build-up and kept protected during the plastering work.

Space for technology without dictating the surface

In addition to the receptacle for the light line, a deeper transformer profile section can house suitable supply technology and connections. This area is planned in with the substructure and cable routing. The visible profile, the cover and the chosen fitting then determine the character of the lighting. In this way, structural preparation and later lighting effect can be handled separately while both belong to one common solution. The available space and the planned service access determine the specific arrangement of the devices.

Clean final assembly after the plastering work

The light unit is only installed once the plaster build-up has been completed and fully dried. Sensitive light components are thus kept separate from damp and dusty work. The suitable insert can be prepared and tested outside the room and, with a planned removal path, remains accessible later. Plaster layers, reinforcement and material connections are coordinated with the clay plaster system used. In this way, the desired lighting effect is combined with the actual construction sequence and long-term access to the technology.

The solution in section

Insights from the construction site

The system as construction progresses.

From the prepared housing to the finished light line.

The path to the finished light line

  1. Check substructure and loads

    Size the ceiling for its own weight and wet plaster. Coordinate the driver zone, cables and profile fixing; do not notch the timber substructure without checking.

  2. Prepare profile and reed

    Align profiles with concrete connectors, fit end caps and feed in cables. Fix OSB and reed mat in accordance with the system; the guide wire sits on the room side.

  3. Apply three plaster layers

    Work the base plaster into the reed mat, create the levelling and reinforcement layer and finally apply the finishing plaster flush with the profile edge. Keep the opening free with the polystyrene protection.

  4. Fit after complete drying

    Remove protection and clean the channel. Insert the prepared light unit with clips matching the fit-out height and secure it separately.

For execution

Installation & documents.

The installation and processing instructions accompany the actual implementation of your line of light.

PDF

Clay plaster · Installation & processing

PDF · matching instructions

PDF

Safety and installation notes

PDF · observe together with the instructions

PDF

The complete installation manual

All applications and system details

Processing notes in detailMounting clips, safety cable and further notes on the specific design

Build-up details

19 mm OSB plus 18 mm plaster build-up give the 37 mm of the mounting profile.

The reed mat of about 10 mm diameter extends into the second plaster coat and is already included in the 18 mm.

The profile back is fastened directly to the timber substructure; OSB connects on both sides. The 64 mm transformer profile additionally needs 27 mm of space behind this mounting plane.

Processing and installation

Mounting clips V2 (20 mm) and V3 (30 mm) may be shortened. Afterwards, both side legs must again taper inwards at an angle and form tips like the original tips. Blunt or straight-cut leg ends cause the clips to break when snapping in. Bevel both legs accordingly, deburr the cut points and check the tip shape before installation. Then check for full snap-in seating and secure hold. Do not use damaged clips. No blanket shortening dimension or cutting angle.

Individual layers, drying times, reinforcement and the connection to aluminium are coordinated with the clay plaster system used. Avoid moisture penetration of the OSB.

The retaining clip of the fall protection locks exclusively into the mounting profile, never into the flush-mount driver profile. If the light line begins with 0.5 or 1 m of driver profile, the upper securing fixing lies only in the adjoining mounting profile. A continuous flush-mount driver profile does not allow this type of securing; every lighting element must still be secured.

Four mounting clips per metre, rounded up and at least two per section. V1: 10 mm, V2: 20 mm, V3: 30 mm – choose to match the actual fit-out height. Secure visible profiles at the start, at every joint and at the end; the connector pair sits in both rear longitudinal slots of the suitable visible profile.

In the flush-mount driver profile, maximum driver installation height is 18 mm; remove the pull-out tab only after complete installation. MPW recommends routing the conduit in at the start of the driver profile, not through the end caps. Keep the electronics, terminal point and inspection access accessible.

Before cutting, measure the temperature of the profile and cover. Allow room for movement at joints and end caps for heating and cooling, and clip in the cover free of stress.

From possibilities to your project

Light line found.
We'll clarify the details together.

Building material, surface and desired lighting effect set the direction. MPW supports you with the right system version and the next steps.

Talk to MPW
References

Light lines in architecture.

Discover implemented LightLineLed solutions in different rooms and building materials.

Discover references

Open original view ↗

What would you like to know?

Enter a search term.

↑
Clay plaster | LightLineLed | MPW