Metal facade / ventilated cladding
Make the facade tangible in the evening too. Integrated light lines draw geometries into metal surfaces and give the building a distinctive presence.

What this solution makes possible.
A precise light line can structure metal cladding without losing sight of the façade construction. The 3 mm flange profile forms the connection for the panel edges. The substructure, panel overhang and connection are dimensioned together.
Flush transition between metal surface and profile edge.
Documented connection principles for bonding, screwing and riveting.
Its own technical space and a secured luminaire insert installed later.
This is how your line of light is made.
Application, construction and benefits – tailored to your architecture.
Structure architecture with precise lines of light
In a metal facade, LightLineLed can pick up joint directions, emphasise entrances or give a building structure at night. The line of light is planned together with the cladding and matched to its finished plane. This creates a clear transition between the metal surface and the light output. Instead of adding lighting to the facade effect as an afterthought, panel grid, light path and technology position are developed together. The visible line thus becomes part of the architectural design.
The wing connection joins panel and profile
The 3 mm wing profile forms the intended connection area for the metal cladding. Load-bearing substructure, panel overhang and connection are matched to one another. The documented principles take bonding, screwing and riveting into account, each with the requirements of the chosen facade system. The benefit for planning lies in a concretely traceable detail: it shows how the panel is brought up to the profile edge and how the light opening can sit in the finished surface.
Provide light housing and technical compartment deliberately
The mounting profile creates the space for the later luminaire insert. A suitable transformer profile section adds the deeper space for control gear and connections. Both areas can be combined along the planned light path. The actual light unit is installed after the facade work, allowing cladding work and lighting installation to be coordinated cleanly. Visible profile and cover determine the visible termination, while the technology position is coordinated with cable routes, heat dissipation and accessibility.
A façade solution with a planned service route
With a suitable combination and planned removal path, the luminaire insert remains accessible later for maintenance. The recessed profile stays in the façade construction. For the specific design, wind loads, material movement, rear ventilation and water management are considered together with the façade contractor. Outdoor suitability refers to the entire lighting and connection situation. LightLineLed thus combines the desired line effect with comprehensible structural preparation and access to the components during later operation.
The solution in section
The system as construction progresses.
From the prepared housing to the finished light line.
The path to the finished light line
Dimension the substructure and fixing
Coordinate dead weight, wind load, panel overhang and fixed and sliding points with the facade design and fastening system.
Connecting installation profiles
Insert lateral connectors, fix profile joints flush and connect the profile to the façade substructure in a load-bearing way using suitable mounting brackets.
Connect metal panels
Align the outer face of the panel flush with the profile edge. With direct bonding, the panel and the prescribed adhesive layer must together fit into the 3 mm setback; otherwise plan a recessed bonding surface. Set screws or rivets according to the system specification.
Completing the luminaire insert
After the facade work, insert the technology and the prepared light unit, secure each section and check the connections and function.
Installation & documents.
The installation and processing instructions accompany the actual implementation of your line of light.
LL2515 + V5-U-2510; LL25 + V5-U-2510; LL35F + matching V5 version for installation only
PDF · matching instructions
Safety and installation notes
PDF · observe together with the instructions
The complete installation manual
All applications and system details
Processing notes in detailMounting clips, safety cable and further notes on the specific design
Build-up details
Load-bearing wall, insulation, wall bracket, aluminium substructure, metal panel and light profile form the build-up shown; a free rear-ventilation space remains behind it.
The support profiles end on both sides next to the LightLineLed wings. The metal panel bridges the gap between substructure and profile wing.
Mounting profile 37 mm, driver profile 63.7 mm high. The flange width is around 20 mm, the setback 3 mm.
Processing and installation
Mounting clips V2 (20 mm) and V3 (30 mm) may be shortened. Afterwards, both side legs must again taper inwards at an angle and form tips like the original tips. Blunt or straight-cut leg ends cause the clips to break when snapping in. Bevel both legs accordingly, deburr the cut points and check the tip shape before installation. Then check for full snap-in seating and secure hold. Do not use damaged clips. No blanket shortening dimension or cutting angle.
Do not reduce adhesive layers beyond what is permitted. Observe edge distances, thread engagement or rivet clamping range, and room for movement.
Keep rear ventilation free behind the transformer profile as well; maintain water drainage, fire barriers and movement joints. Check material pairings for contact corrosion.
The installation manual provides for IP67 drivers outdoors and optionally IP68 full potting of the light insert; the entire version must still be assessed on a project basis.
The retaining clip of the fall protection locks exclusively into the mounting profile, never into the flush-mount driver profile. If the light line begins with 0.5 or 1 m of driver profile, the upper securing fixing lies only in the adjoining mounting profile. A continuous flush-mount driver profile does not allow this type of securing; every lighting element must still be secured.
Four mounting clips per metre, rounded up and at least two per section. V1: 10 mm, V2: 20 mm, V3: 30 mm – choose to match the actual fit-out height. Secure visible profiles at the start, at every joint and at the end; the connector pair sits in both rear longitudinal slots of the suitable visible profile.
In the flush-mount driver profile, maximum driver installation height is 18 mm; remove the pull-out tab only after complete installation. MPW recommends routing the conduit in at the start of the driver profile, not through the end caps. Keep the electronics, terminal point and inspection access accessible.
Outdoor suitability is assessed for the entire detail: weather, condensation, cable entries, terminals, heat dissipation and inspection belong together. IP67/IP68 of individual components is not proof of a driving-rain-tight façade.
Before cutting, measure the temperature of the profile and cover. Allow room for movement at joints and end caps for heating and cooling, and clip in the cover free of stress.
Discover the matching products.
Profiles, covers and accessories together make up your light line. The product pages show versions and matching combinations.

Mounting profile with 3 mm flange
3 mm flange for suitable sheet-metal and façade connections

Driver profile with 3 mm wing
Technical space directly behind the facade line of light

LL25 profile – the all-round visible profile
Consistent design language for recessed, surface-mounted and pendant installations

Recessed and visible profile LL35F
Visible aluminium edge covers the connection joint

Visible profile LL2515
Compact aluminium body with sculptural V5 cover

Corner visible profile LL2511E
45° inclined light-emitting surface for targeted aiming

Mounting clips V1, V2 and V3
Height adjustment within the intended combination

Fall protection for profiles with flange
Connecting and securing at the profile joint
Light line found.
We'll clarify the details together.
Building material, surface and desired lighting effect set the direction. MPW supports you with the right system version and the next steps.
More possibilities for your architecture.
09Timber facade / ventilated rainscreen
Three ways of installing light in the rainscreen timber façade.
11Plaster-base facade, stone & ceramic
Plaster base boards, stone or ceramic – with a matched visible joint.
12Thermal insulation / ETICS
3 mm flange, connection mesh and plaster: light lines in the insulation layer.
The solution. Experienced in the room.
Light lines in the finished room: the images show layout, integration and light effect. Open an image to enlarge the full shot.