Skip to content
Façade · LightLineLed

Plaster-base facade, stone & ceramic

Plaster, stone or ceramic: LightLineLed connects different façade surfaces with a shared lighting idea. The visible termination is chosen to suit the design.

System idea · Plaster-base facade, stone & ceramic
System idea · Plaster-base façade, stone & ceramic
For your architecture

What this solution makes possible.

The light line becomes part of the façade cladding. Exterior-grade plaster base boards connect to the 13 mm flanges; plaster, stone or ceramic define the finished plane. Three joint solutions make the difference between a cleanly visible edge and a deliberately concealed junction easy to understand.

Wing connection for suitable cement-bound or mineral plaster-base boards.

Compensation for thicker surface build-ups with the matching clip height.

Open shadow gap, overlapping cover or aluminium flange as design options.

The solution in detail

This is how your line of light is made.

Application, construction and benefits – tailored to your architecture.

One light line for different façade surfaces

Plaster, stone and ceramic each give a façade its own character. LightLineLed can complement these materials with an integrated light line whose termination is matched to the finished surface. The housing is planned with suitable plaster base boards and the intended covering build-up. This opens up a shared design idea for different façade areas: the light line follows the architecture, while the material, colour and texture of the cladding continue to define the surface.

Choose the visible connection deliberately

The system variants allow different joint patterns. LL25 with a narrow cover leaves a deliberately formed shadow gap visible. Matching V2 or V3 covers can conceal the junction; LL35F takes on this task with its aluminium flanges. These installation variants differ in their effect on the surface. The decision can therefore be made based on the desired appearance: a clearly visible edge, a concealed transition or a light exit framed by aluminium.

The build-up depends on the finished surface

The wings of the installation profile sit behind the plaster-base board. The board remains fixed to its substructure as usual and is additionally connected to the intended profile wing. Reinforcement, plaster, adhesive and covering together determine the final surface. Within the matching system combination, the selected clip height takes this build-up into account. This allows the light housing to be prepared early, while the final position of the luminaire insert relates to the surface actually produced.

Finish surfaces and insert the light later

During the facade work, an insert protects the profile opening. The prepared light unit follows once the surface is finished and remains accessible where a service route is planned. The client thus gets a coordinated connection between facade material and lighting design. Panel suitability, movement joints, fixing and outdoor suitability are clarified with the respective facade system. The section drawings help to select the suitable connection variant and to understand the relationship between surface, profile and visible line of light.

The solution in section

Insights from the construction site

The system as construction progresses.

From the prepared housing to the finished light line.

The path to the finished light line

  1. Choose the build-up and connection

    Take the board, reinforcement, plaster or adhesive and finish into account together. Provide an open joint only if the visible edge will remain permanently clean; otherwise ensure sufficient overlap.

  2. Fix profile and boards

    Size the substructure and loads, mount the profile flush and fix boards in the usual way to the substructure and on both sides at the wing.

  3. Complete the surface

    Protect the profile opening and execute joints, mesh and plaster in accordance with the system. Keep movement joints and locking areas free.

  4. Adjust the clip and insert the light

    Mounting clips V2 (20 mm) and V3 (30 mm) may be shortened. Afterwards, both side legs must again taper inwards at an angle and form tips like the original tips. Blunt or straight-cut leg ends cause the clips to break when snapping in. Bevel both legs accordingly, deburr the cut edges and check the tip shape before inserting. Then check for full locking seat and secure hold. Do not use damaged clips. No blanket shortening dimension or cutting angle. Secure and insert the light insert.

For execution

Installation & documents.

The installation and processing instructions accompany the actual implementation of your line of light.

PDF

Plaster-base façade, stone & ceramic · Installation & processing

PDF · matching instructions

PDF

Safety and installation notes

PDF · observe together with the instructions

PDF

The complete installation manual

All applications and system details

Processing notes in detailMounting clips, safety cable and further notes on the specific design

Build-up details

The flanges lie behind the board. On each side, screw from the outside through the plaster-base board into the associated flange; the regular board fixing to the façade substructure remains in place.

13 mm refers to the flange height, not the maximum possible build-up height. What matters are the finished surface, the latching and the matching V2/V3 clip.

LL25 with a narrow cover needs a finished straight visible edge. LL25 with V2/V3 can cover the joint. LL35F covers it with aluminium wings.

Processing and installation

Mounting clips V2 (20 mm) and V3 (30 mm) may be shortened. Afterwards, both side legs must again taper inwards at an angle and form tips like the original tips. Blunt or straight-cut leg ends cause the clips to break when snapping in. Bevel both legs accordingly, deburr the cut points and check the tip shape before installation. Then check for full snap-in seating and secure hold. Do not use damaged clips. No blanket shortening dimension or cutting angle.

No blanket shortening dimension or angle for the V2/V3 mounting clips. The examples shown do not replace sampling.

Do not plaster over the LL35F flange or connect it rigidly to the finish. A covered joint alone is not a seal.

Separately anchored stone panels remain on their own substructure; fix the light profile independently. Maintain rear ventilation, drainage paths and fire barriers.

The retaining clip of the fall protection locks exclusively into the mounting profile, never into the flush-mount driver profile. If the light line begins with 0.5 or 1 m of driver profile, the upper securing fixing lies only in the adjoining mounting profile. A continuous flush-mount driver profile does not allow this type of securing; every lighting element must still be secured.

Four mounting clips per metre, rounded up and at least two per section. V1: 10 mm, V2: 20 mm, V3: 30 mm – choose to match the actual fit-out height. Secure visible profiles at the start, at every joint and at the end; the connector pair sits in both rear longitudinal slots of the suitable visible profile.

In the flush-mount driver profile, maximum driver installation height is 18 mm; remove the pull-out tab only after complete installation. MPW recommends routing the conduit in at the start of the driver profile, not through the end caps. Keep the electronics, terminal point and inspection access accessible.

Outdoor suitability is assessed for the entire detail: weather, condensation, cable entries, terminals, heat dissipation and inspection belong together. IP67/IP68 of individual components is not proof of a driving-rain-tight façade.

Before cutting, measure the temperature of the profile and cover. Allow room for movement at joints and end caps for heating and cooling, and clip in the cover free of stress.

From possibilities to your project

Light line found.
We'll clarify the details together.

Building material, surface and desired lighting effect set the direction. MPW supports you with the right system version and the next steps.

Talk to MPW
References

Light lines in architecture.

Discover implemented LightLineLed solutions in different rooms and building materials.

Discover references

Open original view ↗

What would you like to know?

Enter a search term.

↑
Plaster-base façade, stone & ceramic | LightLineLed | MPW